Resilient power infrastructure for an availability-focused datacenter

Coordinated backup-power infrastructure for a critical datacenter facility, supporting the bank's ambition to operate an availability-focused, Tier III-aligned datacenter.

Client
Siinqee Bank
Sector
Banking and Financial Services
Location
Siinqee Bank Headquarters
Completion
2024
Status
Completed
Technology
Cummins, KSTAR
Illustration: Siinqee Bank Datacenter Facility and Power Solutions sample image

Client context

The need

A bank's datacenter depends on continuous, conditioned power. Grid interruption, voltage instability, equipment faults, or maintenance can affect digital banking services and critical information systems. Siinqee Bank required a stronger power architecture aligned with its wider datacenter availability goals.

Project scope

What Edge Comm-Tech delivered

  • 01Critical-load assessment, capacity planning, autonomy requirements, redundancy, and growth review.
  • 02KSTAR uninterruptible power infrastructure for conditioned power and transition support.
  • 03Cummins diesel-generator infrastructure for extended backup generation.
  • 04Electrical distribution, protection, grounding, transfer, monitoring, and integration within the approved scope.
  • 05Installation coordination, configuration, staged testing, commissioning, documentation, and handover.
  • 06Operator training, maintenance guidance, warranty, and support preparation.

Delivered solution

An integrated operational solution

Uninterruptible power layer

KSTAR UPS systems condition power and support critical loads through short interruptions and the transition to backup generation, according to the accepted runtime and redundancy design.

Extended backup generation

Cummins generator infrastructure provides an alternative power source for longer grid outages, supported by the approved transfer and operating arrangements.

Coordinated power path

UPS, generation, distribution, protection, grounding, monitoring, and operating procedures work together as a system rather than as separate equipment purchases.

Maintainability and readiness

Testing, documentation, training, and maintenance planning help the bank operate and service the infrastructure with controlled risk.

Tier-aligned direction

The delivered power improvements support the bank's wider ambition for an availability-focused Tier III-aligned datacenter.

Implementation

From assessment to operational handover

Edge Comm-Tech coordinated the project across requirements validation, detailed design, sourcing, logistics, site preparation, installation, configuration, integration, testing, issue resolution, client acceptance, documentation, training, and handover.

Outcomes

The result

  • A more resilient and redundant power foundation for critical datacenter operations.
  • Reduced exposure to grid interruption and unstable power conditions.
  • Improved transition from utility power to protected and generated backup power.
  • Better operational readiness through testing, monitoring, documentation, and training.
  • A stronger facility foundation for the bank's wider datacenter availability and growth objectives.

Technology

Cummins diesel generators and KSTAR UPS systems.

  • Cummins
  • KSTAR

Training and handover

Local technical and operational training was provided to designated bank personnel, with training-completion certificates issued as applicable.

Tier III-aligned describes the design direction. Tier III certification is stated separately only if awarded by an authorized independent body.